D70M Mobile Vaccine Fridge

70L mobile vaccine fridge | 2°C to 8°C | 26-hour eutectic holdover at 32°C | operates on 12/24V DC or 220V AC | ideal for mobile clinics, outreach programmes, and remote healthcare facilities

The D70M is a 70-litre mobile vaccine refrigerator designed to maintain a reliable 2°C to 8°C temperature range during transit and in field operations. Built specifically for mobile cold-chain delivery, it is engineered to withstand the demanding conditions encountered during transport and in field clinics across Southern Africa. Developed and manufactured in South Africa to Global Health Cold Chain specifications with support from the South African National Department of Health, it is a purpose-built solution for mobile clinics, outreach programmes, and healthcare facilities operating in areas with unreliable electricity supply.

The cabinet is constructed in stainless steel — exterior and interior — for durability, hygiene, and ease of cleaning in field conditions. CFC-free high-density foam insulation supports thermal retention, and the upright format improves access and stock management during field operations. A pre-fitted probe hole supports integration with independent temperature monitoring devices for cold-chain verification and compliance.

Eutectic tanks embedded within the fridge walls sustain cold conditions for up to 26 hours at 32°C ambient temperature when electrical power is interrupted. Combined with dual power capability — operating on 12/24V DC from vehicles or switching to 220V AC from mains — the D70M supports continuous cold-chain integrity from loading through to arrival and operation at a remote site. A PLC controller maintains cabinet temperature to the 2°C to 8°C setpoint with ±2°C accuracy. Anti-freeze protection helps prevent accidental freezing of vaccines and temperature-sensitive medicines.

Backed by Minus40’s service support, with optional maintenance agreements available.

Features

  • 26-hour eutectic holdover at 32°C using embedded eutectic tanks for cold-chain continuity when power is interrupted
  • Dual power capability — operates on 12/24V DC from vehicles or 220V AC from mains
  • Developed to Global Health Cold Chain specifications — with Department of Health support
  • PLC temperature controller maintaining 2°C to 8°C setpoint with ±2°C accuracy
  • Solar-powered display showing cabinet temperature when mains power is unavailable
  • Anti-freeze protection preventing accidental freezing of vaccines and temperature-sensitive medicines
  • Stainless steel interior and exterior for hygiene and durability in field conditions
  • Upright design for ease of access and stock management during field operations
  • Robust construction engineered to withstand harsh driving conditions
  • Pre-fitted probe hole for independent temperature monitoring and cold-chain compliance

Safety

Audible and visual temperature alarms alert staff when cabinet conditions fall outside the 2°C to 8°C operating range. A door-open alarm reduces the risk of inadvertent temperature excursions during transit and field operation. Anti-freeze protection helps prevent temperatures that could damage vaccines and biological products. Built-in voltage protection safeguards the compressor and control systems against electrical supply fluctuations. The lockable latch restricts unauthorised access during transport and in field environments.

Temperature Control

The D70M uses a PLC controller to maintain a stable 2°C to 8°C temperature range with ±2°C accuracy. Eutectic tanks embedded within the fridge walls sustain cold conditions for up to 26 hours at 32°C ambient temperature following a power interruption. An additional solar-powered display shows cabinet temperature when no mains power is present, supporting cold-chain monitoring during transit without opening the unit. The D70M operates on 12/24V DC from a vehicle power supply or switches to 220V AC from mains. Automatic defrost helps prevent ice accumulation on the evaporator, maintaining consistent cooling performance.

Use Cases

  • Mobile Clinics & Outreach Programmes
    • Cold-chain compliant vaccine transport from central storage to remote vaccination sites
    • Continuous operation on vehicle DC during transit, switching to mains AC on arrival
    • 26-hour eutectic holdover maintains cold-chain integrity if power is unavailable at the destination
  • Remote & Rural Healthcare Facilities
    • Reliable vaccine storage in facilities with unreliable or intermittent electrical supply
    • Eutectic holdover bridges power outages without compromising cold-chain integrity
  • Emergency & Disaster Response
    • Rapid deployment of vaccine cold-chain capacity to areas without reliable infrastructure
    • Dual power capability supports operation in diverse field environments
  • Public Health Programmes
    • Cold-chain verified transport supporting immunisation programme requirements
    • Suitable for Department of Health and NGO mobile vaccination campaigns
  • Field Clinics & Community Health Outreach
    • Upright format provides stock access and management during consultations
    • Robust stainless steel construction withstands repeated transport and field use
  • Veterinary Field Services
    • Cold-chain compliant transport of veterinary vaccines and biological products
    • Vehicle-powered operation for farm visits and remote animal health outreach

Model

Model Name D70M Mobile Vaccine Fridge
Cabinet Type Upright
Capacity (L) 70L

Construction

External Material Stainless steel
Internal Material Stainless steel
Insulation CFC-free high-density foam insulation
Shelves 2 fixed perforated stainless steel shelves
Door Type Solid hinged door (self-closing)
Door Lock Lockable latch
Lighting Internal LED (activated on door opening)
Light Switch No external light switch
Probe Hole Pre-fitted independent temperature monitoring probe hole
Feet / Base of Unit Levelling feet

Refrigeration

Compressor(s) 1 compressor
Cooling Method Fan-assisted cooling with eutectic tank holdover
Defrost Mode Automatic defrost
Refrigerant R134a

Alarms

Temperature Alarm Audible and visual alarm for temperatures outside 2°C to 8°C
Dirty Condenser Alarm N/A
Door Alarm Audible and visual alarm

Performance

Temperature Range 2°C to 8°C
Max Ambient Temperature 32°C
Holdover Time at 32°C (Hr) 26 hours (eutectic)
Controller(s) 1 PLC digital controller with LED display; 1 additional solar display
Temperature Accuracy ±2°C

Dimensions

External Dimensions (H x W x D mm) 835 x 600 x 695
Internal Dimensions (H x W x D mm) 515 x 400 x 350
Weight (kg) 75

Electrical

Voltage 220V AC / 12/24V DC
Rated Power Supply (A) 0.17A (220V AC)
Electrical Protection Built-in voltage protector
Energy Rating Est. A+
Leave your details below & we will contact you with a comprehensive quote:

The D70M is a 70-litre mobile vaccine refrigerator designed to maintain a reliable 2°C to 8°C temperature range during transit and in field operations. Built specifically for mobile cold-chain delivery, it is engineered to withstand the demanding conditions encountered during transport and in field clinics across Southern Africa. Developed and manufactured in South Africa to Global Health Cold Chain specifications with support from the South African National Department of Health, it is a purpose-built solution for mobile clinics, outreach programmes, and healthcare facilities operating in areas with unreliable electricity supply.

The cabinet is constructed in stainless steel — exterior and interior — for durability, hygiene, and ease of cleaning in field conditions. CFC-free high-density foam insulation supports thermal retention, and the upright format improves access and stock management during field operations. A pre-fitted probe hole supports integration with independent temperature monitoring devices for cold-chain verification and compliance.

Eutectic tanks embedded within the fridge walls sustain cold conditions for up to 26 hours at 32°C ambient temperature when electrical power is interrupted. Combined with dual power capability — operating on 12/24V DC from vehicles or switching to 220V AC from mains — the D70M supports continuous cold-chain integrity from loading through to arrival and operation at a remote site. A PLC controller maintains cabinet temperature to the 2°C to 8°C setpoint with ±2°C accuracy. Anti-freeze protection helps prevent accidental freezing of vaccines and temperature-sensitive medicines.

Backed by Minus40’s service support, with optional maintenance agreements available.

Features

  • 26-hour eutectic holdover at 32°C using embedded eutectic tanks for cold-chain continuity when power is interrupted
  • Dual power capability — operates on 12/24V DC from vehicles or 220V AC from mains
  • Developed to Global Health Cold Chain specifications — with Department of Health support
  • PLC temperature controller maintaining 2°C to 8°C setpoint with ±2°C accuracy
  • Solar-powered display showing cabinet temperature when mains power is unavailable
  • Anti-freeze protection preventing accidental freezing of vaccines and temperature-sensitive medicines
  • Stainless steel interior and exterior for hygiene and durability in field conditions
  • Upright design for ease of access and stock management during field operations
  • Robust construction engineered to withstand harsh driving conditions
  • Pre-fitted probe hole for independent temperature monitoring and cold-chain compliance

Safety

Audible and visual temperature alarms alert staff when cabinet conditions fall outside the 2°C to 8°C operating range. A door-open alarm reduces the risk of inadvertent temperature excursions during transit and field operation. Anti-freeze protection helps prevent temperatures that could damage vaccines and biological products. Built-in voltage protection safeguards the compressor and control systems against electrical supply fluctuations. The lockable latch restricts unauthorised access during transport and in field environments.

Temperature Control

The D70M uses a PLC controller to maintain a stable 2°C to 8°C temperature range with ±2°C accuracy. Eutectic tanks embedded within the fridge walls sustain cold conditions for up to 26 hours at 32°C ambient temperature following a power interruption. An additional solar-powered display shows cabinet temperature when no mains power is present, supporting cold-chain monitoring during transit without opening the unit. The D70M operates on 12/24V DC from a vehicle power supply or switches to 220V AC from mains. Automatic defrost helps prevent ice accumulation on the evaporator, maintaining consistent cooling performance.

Use Cases

  • Mobile Clinics & Outreach Programmes
    • Cold-chain compliant vaccine transport from central storage to remote vaccination sites
    • Continuous operation on vehicle DC during transit, switching to mains AC on arrival
    • 26-hour eutectic holdover maintains cold-chain integrity if power is unavailable at the destination
  • Remote & Rural Healthcare Facilities
    • Reliable vaccine storage in facilities with unreliable or intermittent electrical supply
    • Eutectic holdover bridges power outages without compromising cold-chain integrity
  • Emergency & Disaster Response
    • Rapid deployment of vaccine cold-chain capacity to areas without reliable infrastructure
    • Dual power capability supports operation in diverse field environments
  • Public Health Programmes
    • Cold-chain verified transport supporting immunisation programme requirements
    • Suitable for Department of Health and NGO mobile vaccination campaigns
  • Field Clinics & Community Health Outreach
    • Upright format provides stock access and management during consultations
    • Robust stainless steel construction withstands repeated transport and field use
  • Veterinary Field Services
    • Cold-chain compliant transport of veterinary vaccines and biological products
    • Vehicle-powered operation for farm visits and remote animal health outreach

Model

Model Name D70M Mobile Vaccine Fridge
Cabinet Type Upright
Capacity (L) 70L

Construction

External Material Stainless steel
Internal Material Stainless steel
Insulation CFC-free high-density foam insulation
Shelves 2 fixed perforated stainless steel shelves
Door Type Solid hinged door (self-closing)
Door Lock Lockable latch
Lighting Internal LED (activated on door opening)
Light Switch No external light switch
Probe Hole Pre-fitted independent temperature monitoring probe hole
Feet / Base of Unit Levelling feet

Refrigeration

Compressor(s) 1 compressor
Cooling Method Fan-assisted cooling with eutectic tank holdover
Defrost Mode Automatic defrost
Refrigerant R134a

Alarms

Temperature Alarm Audible and visual alarm for temperatures outside 2°C to 8°C
Dirty Condenser Alarm N/A
Door Alarm Audible and visual alarm

Performance

Temperature Range 2°C to 8°C
Max Ambient Temperature 32°C
Holdover Time at 32°C (Hr) 26 hours (eutectic)
Controller(s) 1 PLC digital controller with LED display; 1 additional solar display
Temperature Accuracy ±2°C

Dimensions

External Dimensions (H x W x D mm) 835 x 600 x 695
Internal Dimensions (H x W x D mm) 515 x 400 x 350
Weight (kg) 75

Electrical

Voltage 220V AC / 12/24V DC
Rated Power Supply (A) 0.17A (220V AC)
Electrical Protection Built-in voltage protector
Energy Rating Est. A+
Leave your details below & we will contact you with a comprehensive quote: